Medium - Inspection Needed

Maytag Microwave F3T2 Code (Convection Thermistor)

Maytag gives F3T2 as a possible problem with the convection thermistor or the associated wiring. It applies to models with a convection function, where a fan circulates heated air, and the thermistor tells the control what temperature that air has…

What F3T2 Means

Maytag gives F3T2 as a possible problem with the convection thermistor or the associated wiring. It applies to models with a convection function, where a fan circulates heated air, and the thermistor tells the control what temperature that air has reached.

Common Causes of F3T2

  • Transient fault cleared by a reset
  • Thermistor connector loose
  • Wiring heat-damaged near the convection heater
  • Convection thermistor failed

🔧 One Safe Check You Can Try

Switch the microwave off at its circuit breaker for one minute, restore power, then run a short heating test with a cup of water to verify operation, which is the check Maytag asks for. Test the plain microwave function separately with a cup of water, because it usually works independently of the convection side, and knowing that narrows the fault before anyone visits. Avoid convection programmes until the thermistor is replaced - running convection without reliable temperature feedback means the control cannot regulate the heat properly.

⚠ Why You Shouldn't Go Further Than That

  • A microwave oven holds a high voltage capacitor that can retain a dangerous charge long after the appliance is unplugged, so the cabinet is never opened at home under any circumstances.
  • An over-the-range unit is mounted above a cooking surface at head height and is heavy enough to need two people and a support to remove safely.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Microwave Error Codes

Related Guides

Still Seeing F3T2?

Book a factory-trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

Book Repair for F3T2

Same-day & next-day appointments · No hidden fees · Factory-trained technicians

1Service Details
2Date & Time
3Contact Info

or call (844) 681-4628 now

FAQ

F3T2 FAQ

It is published for convection models. If yours has no such function, note that when you book.

Usually not, which is a useful test to run.

Need a repair? We're ready to help. Call Now
Call Us Schedule